The C-Arm 6 with FPD DOXA Series DR Plus machine is manufactured and exported by us across West Bengal at cost-effective prices. You can use our C-Arm machines in your multispeciality hospitals and healthcare centers. This C-Arm machine comes with a generator capacity of 3.5 KW with a consumption of 220 volts of voltage. Our C-Arm machine is available in a highly compact and ergonomic design with intuitive positioning which assures its functionality at a greater level. It works on a frequency of 50 Hz. Our machine provides superb image quality on the LED Monitor attached to the machine. It is fixed with a USB memory stick which helps in keeping the backup of the images captured. You can permanently store about 100 images in our FPD DOXA machine.
High-Frequency C-Arm machine diagnostic equipment for general-purpose fluoroscopy, it is designed for Orthopaedics, Neurology, Cardiology, Gastroenterology MAKE: X-TECH MEDICAL SYSTEMS Pvt. Ltd. (AERB, BIS, Compliance with FDA & CE & IEC60601-2-52-2009, ISO 9001:2015, ISO 13485:2016, ISO 14001:2015, ISO 10002:2014, ISO 45001:2018 APPROVED).
OUTPUT
Model | DOXA SERIES DR PLUS(Micro Processor Controlled C-Arm Machine with Excellent Image Quality at Low Radiation) |
SENSOR
Panel | Amorphous silicon active TFT/diode array |
Scintillator | Direct-Deposit CsI: TI |
Effective Active Area | 236.5x236.5mm |
Pixel Pitch | 154 μm |
Limiting Resolution | 3.2Ip/mm (1x1), 1.6Ip/mm(2x2) |
Pixel Array | 1536x1536 |
ELECTRONICS
A/D Conversion | 16bit (12bit optional) |
Gain | 3 |
Mode | Pulsed/ Continuous |
Trigger Type |
Matrix Binning |
Matrix | Field of View(mm) |
Frame rate(fps) |
|
Read-out mode | Fluoroscopy | ||||||
(P mode: 12 msec X-ray pulse window) |
1 | P | External | 1 x 1 | 1536 x 1536 | 236.5 x 236.5 | 12 |
2 | P | External | 2 x 2 | 768 x 768 | 236.5 x 236.5 | 25 | |
3 | C | External | 1 x 1 | 1536 x 1536 | 236.5 x 236.5 | 15 | |
4 | C | External | 2 x 2 | 768 x 768 | 236.5 x 236.5 | 30 |
MECHANICAL
Size | 280 x 280 x 45.8mm |
Weight | ~3.2Kg |
Housing | Anodized aluminum alloy |
Ingress Protection | IP30 |
COMMUNICATION
Data I/F | Gigabit Ethernet |
X-ray I/F | Integrated X-ray trigger control (TTL 5V or 12V) |
IMAGE PERFORMANCE
DQE (1x1 @ RQA 5, 0.9 μGy) | ~80% (@0.0 lp/mm), ~65% (@1.0 lp/mm), ~43% (@2.0 lp/mm), ~22% (@3.0 lp/mm) |
MTF(1x1) | ~60% (@1.0 lp/mm),~28% (@2.0 lp/mm),~12% (@3.0 lp/mm) |
Lag | 1st frame<2.5%, 2nd frame<0.5% |
Quantum Limited Dose | 3.0 nGy/frame (1x1), 1.5 nGy/frame (2x2) |
Dynamic Range | >70 dB high gain (1x1),> 93 dB low gain(1x1) >60 dB high gain (2x2),> 90 dB low gain(2x2) |
Energy | 15-ISOKV |
ENVIRONMENTAL
Temperature | Operating:10~40 °C, Storage:-20~55 °C |
Humidity | Operating:30~75% RH (Non-condensing), Storage: 10~90% RH |
POWER
Power Supply | 240V AC, 50/60Hz |
Maximum Power | ~20W |
CONTROL PANEL
LCD DISPLAY: Very compact, soft touch contact panel with 20x3(Columns x Rows) LCD on which kV, mAs, fluoro mA, and various errors (example:- kV error, filament error & thermal error are displayed on LCD screen for self-diagnosis.
Control Panel Has Following Functions And Indications:-
PATIENT ADMINISTRATION
IMAGE ACQUISITION
OPERATING MODES:- Normal Fluoro; Snapshot(Single image for better image quality)
LIVE IMAGE PROCESSING
IMAGE STORAGE
IMAGE POST-PROCESSING
ON SCREEN DISPLAY
REMOTE CONTROL: Most used functions can be controlled via Remote Control
UNIQUE FEATURES-ARTIFICIAL INTELLIGENCE ENABLED
EXPORT MEDIA
MONITOR: 27 inches
C-Arm Movement
Maximum output: 6 kW
Maximum mA output: 18mA in fluoro/30mA boost/100mA in radio
KV control: 40- 120 kV
Power input: 220V AC, 50 HZ, 16A
Digital Display: mA, S & kV
Fault Finding: Self Diagnostics
Overload Protection: Simultaneous Protection from the input voltage.
Voltage compensation: AUTOMATIC
Large FOV: The 560RF has an active region of 23.6x23.6cm (9.3x9.3in), a larger field of view that dramatically increases imaging area capacity.
Versatile Design: Compact, slender panels provide more free space for C-Arm modalities. Lightweight and convenient for diverse applications.
Advanced Technology: Direct-Deposit Csl combined with a precise balance of engineering factors. Panels developed for highly detailed, low-dose diagnostic imaging.
TIALIC: More efficient workflow with CareRay’s patented TIALIC (Time-Independent Adaptive Low-Dose Image Correction) technology. Avoid low signal-to-noise Ratios caused by insufficient high-voltage power.
Phone Number
Email Address
Location
X-TECH MEDICAL SYSTEMS PRIVATE LIMITED
Nandipukur More, Adisaptagram, Railway Level Crossing,
Choto Khejuria, Kolkata, West Bengal,
Kolkata - 712121